Common Issues
| Problem | Possible Cause | Solution |
|---|---|---|
| No green power LED | Power issue | Check connection to RS2+, verify RS2+ is powered on |
| No blinking orange LED | Data transmission issue | Verify RS232 output is enabled in ReachView app |
| Poor range performance | Environmental obstacles | Reposition base station with better line of sight |
| Intermittent connection | Interference | Change location, check for sources of RF interference |
| Rover not receiving corrections | Configuration mismatch | Verify rover is configured to receive on correct frequency |
Advanced Troubleshooting
If basic troubleshooting doesn't resolve your issue:
- Try power cycling both the Emlid Reach RS2+ and reconnecting the Radio Module
- Check for firmware updates for your Emlid Reach RS2+
- Verify compatibility settings between base and rover devices
- Check antenna connections and placement